{"id":1741,"date":"2025-10-06T16:53:58","date_gmt":"2025-10-06T14:53:58","guid":{"rendered":"http:\/\/www.thermodynamx.ch\/zimmer-medizinsysteme-cryo-6-7\/"},"modified":"2025-11-25T17:23:33","modified_gmt":"2025-11-25T16:23:33","slug":"en-cryo-medizinsysteme","status":"publish","type":"page","link":"https:\/\/www.thermodynamx.ch\/en\/en-cryo-medizinsysteme\/","title":{"rendered":"Cryo Medical Systems"},"content":{"rendered":"\n\t<section id=\"intro-text-block_63b6ee27beea42906a7b6bdcef3365d1\" class=\"intro-text\">\n\t\t<div class=\"container\">\n\n\t\t\t<h1>\u00a0Cryo \u2013 Coldtherapy with natural refrigerants<\/h1>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p class=\"tdx-intro\">ThermodynamX supports the conversion of<br \/>\ncryotherapy device families to natural refrigerants \u2013 for<br \/>\nfuture-proof compliance and efficient, quiet cooling in everyday practice.<\/p>\n<img decoding=\"async\" src=\"https:\/\/www.thermodynamx.ch\/wp-content\/uploads\/images\/david-dibert-nrX-gcVw8nE-unsplash-scaled.jpg\" alt=\"\" \/>\n\t\t<\/div>\n\t\t<!-- \/.container -->\n\n\t\t<div class=\"intro-text-bottom\"><div class=\"container container--narrow\"><p>&nbsp;<\/p>\n<section class=\"tdx-quote\" aria-label=\"Projektkontext\">\n<blockquote><p>\u201cBy switching to natural refrigerants, we ensure performance, efficiency and availability \u2013 with reduced<br \/>\nregulatory risk over the life cycle.\u201d<\/p>\n<footer>\u2014 ThermodynamX Projectteam<\/footer>\n<\/blockquote>\n<\/section>\n<\/div>\n\t\t\t<!-- \/.container container--narrow --><\/div><!-- \/.intro-text-bottom -->\n\t\t\t<\/section> <!--  .intro-text -->\n\n\n\n\n\t\t<section id=\"content-block_a2b6203a7462a6cb3f77879f78189672\" class=\"content\" style=\"background-color: #FFFFFF;\">\n\t\t\t<div class=\"container\">\n\t\t\t\t<div class=\"flex-row\">\n\n\t\t\t\t\t\n\t\t\t\t\t\t<div class=\"col-6@md\">\n\n\t\t\t\t\t\t\t<p>&nbsp;<\/p>\n<div class=\"tdx-col\">\n<h2>Background<\/h2>\n<p>Existing cryogenic systems were based on synthetic refrigerants.<\/p>\n<p>The market environment demands sustainable alternatives with lower regulatory risk.<\/p>\n<p>High demands are placed on performance, noise, and size in the medical technology sector.<\/p>\n<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<!--  .col-6@md -->\n\n\t\t\t\t\t\n\t\t\t\t\t\t<div class=\"col-6@md\">\n\n\t\t\t\t\t\t\t<p>&nbsp;<\/p>\n<h4>Project Goals<\/h4>\n<p>&#8211; Near-drop-in conversion to natural refrigerants (e.g., R290) without compromising clinical performance.<\/p>\n<p>&#8211; Reduction of noise and vibration emissions through optimized installation and airflow.<\/p>\n<p>&#8211; Increased efficiency through a capacity-controlled refrigeration system and optimized airflow.<\/p>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<!--  .col-6@md -->\n\n\t\t\t\t\t\n\t\t\t\t\t\t<div class=\"col-12\">\n\n\t\t\t\t\t\t\t<section class=\"tdx-story\">\n<h4><strong>The challenge<\/strong><\/h4>\n<p>In cryotherapy, constant cold air temperatures, short response times, and low noise levels must be achieved simultaneously.<br \/>\nThe switch to natural refrigerants should be accomplished without compromising user comfort, safety, or ease of maintenance.<\/p>\n<h4><strong>The solution<\/strong><\/h4>\n<p>ThermodynamX designed a natural refrigerant refrigeration circuit with<br \/>\nvariable-capacity compression, acoustically decoupled assembly, and adapted<br \/>\nheat exchanger design. The concept addresses charging\/filling volumes, leakage prevention, ignition source distances, and<br \/>\nservice-friendly integration \u2013 including a measurement and test setup for verification\/validation.<\/p>\n<\/section>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<!--  .col-12 -->\n\n\t\t\t\t\t\n\t\t\t\t\t\t<div class=\"col-6@md\">\n\n\t\t\t\t\t\t\t<p>&nbsp;<\/p>\n<h4><strong>The result<\/strong><\/h4>\n<p>The new design enables stable cooling performance with reduced energy consumption and<br \/>\nlower noise levels. The use of natural refrigerants reduces regulatory risk<br \/>\nover the product lifecycle \u2013 a benefit for operators, service providers, and end users.<\/p>\n<section class=\"tdx-grid\" aria-label=\"Technische Eckdaten und Merkmale\">\n<div class=\"tdx-col\">\n<h4>Technical Specifications (Example Frame)<\/h4>\n<p>&#8211; Refrigerant: R290 (optimized charge, low GWP)<br \/>\n&#8211; Control: variable output (high part-load efficiency)<br \/>\n&#8211; Acoustics: encapsulated compressor assembly, flow-optimized airflow<br \/>\n&#8211; Service: modular design, good component accessibility<\/p>\n<\/div>\n<div class=\"tdx-col\">\n<h4>Special features<\/h4>\n<p>&#8211; Sustainability: natural refrigerants instead of HFCs<\/p>\n<p>&#8211; Compliance-ready: designed to meet current and future-proof requirements<br \/>\n&#8211; Practical: compact form factor, quiet operation<br \/>\n&#8211; Validated: measurement and test protocols and documentation for approvals<\/p>\n<\/div>\n<\/section>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<!--  .col-6@md -->\n\n\t\t\t\t\t\n\t\t\t\t<\/div>\n\t\t\t\t<!--  .flex-row -->\n\t\t\t<\/div> <!--  .container -->\n\n\t\t\t\n\t\t<style>\n\t\t\tsection#content-block_a2b6203a7462a6cb3f77879f78189672 {\n\t\t\t\tpadding-bottom:154px;\t\t\t}\n\t\t\t\/* TABLET *\/\n\t\t\t@media only screen and (max-width: 768px) {\n\t\t\t\tsection#content-block_a2b6203a7462a6cb3f77879f78189672 {\n\t\t\t\t\tpadding-bottom:20px;\t\t\t\t}\n\t\t\t}\n\t\t\t\/* MOBILE *\/\n\t\t\t@media only screen and (max-width: 600px) {\n\t\t\t\tsection#content-block_a2b6203a7462a6cb3f77879f78189672 {\n\t\t\t\t\t\t\t\t\t}\n\t\t\t}\n\t\t<\/style>\n\n\t\t\t<\/section>\n\t\t<!--  .content -->\n\n\t\n\n\n\t\t<section id=\"content-block_6ee319d473c899c6e40f3c0d232c3853\" class=\"content\" style=\"background-color: #f9f9f9;\">\n\t\t\t<div class=\"container\">\n\t\t\t\t<div class=\"flex-row\">\n\n\t\t\t\t\t\n\t\t\t\t\t\t<div class=\"col-12\">\n\n\t\t\t\t\t\t\t<h2 style=\"text-align: center;\"><span class=\"sqsrte-text-color--custom\" style=\"font-size: 70px;\"><strong>Cool solutions for hot results.<\/strong><\/span><\/h2>\n<p style=\"text-align: center;\">We step in whenever thermally complex, sustainable and market-ready solutions are needed.<\/p>\n<p style=\"text-align: center;\"><a class=\"btn btn-primary\" href=\"http:\/\/www.thermodynamx.ch\/en\/offer\/\" target=\"_blank\" rel=\"noopener\">Our Offers<\/a><\/p>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<!--  .col-12 -->\n\n\t\t\t\t\t\n\t\t\t\t<\/div>\n\t\t\t\t<!--  .flex-row -->\n\t\t\t<\/div> <!--  .container -->\n\n\t\t\t\n\t\t<style>\n\t\t\tsection#content-block_6ee319d473c899c6e40f3c0d232c3853 {\n\t\t\t\tpadding-bottom:80px;\t\t\t}\n\t\t\t\/* TABLET *\/\n\t\t\t@media only screen and (max-width: 768px) {\n\t\t\t\tsection#content-block_6ee319d473c899c6e40f3c0d232c3853 {\n\t\t\t\t\t\t\t\t\t}\n\t\t\t}\n\t\t\t\/* MOBILE *\/\n\t\t\t@media only screen and (max-width: 600px) {\n\t\t\t\tsection#content-block_6ee319d473c899c6e40f3c0d232c3853 {\n\t\t\t\t\t\t\t\t\t}\n\t\t\t}\n\t\t<\/style>\n\n\t\t\t<\/section>\n\t\t<!--  .content -->\n\n\t","protected":false},"excerpt":{"rendered":"","protected":false},"author":5,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"_seopress_robots_primary_cat":"","_seopress_titles_title":"Cryo Medical Systems \u2013 ThermodynamX","_seopress_titles_desc":"Reliable cryogenic cooling systems for medical devices. Explore our cryotechnology solutions.","_seopress_robots_index":"","footnotes":""},"class_list":["post-1741","page","type-page","status-publish","hentry","no-post-thumbnail","post-count-1"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.thermodynamx.ch\/en\/wp-json\/wp\/v2\/pages\/1741","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermodynamx.ch\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.thermodynamx.ch\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermodynamx.ch\/en\/wp-json\/wp\/v2\/users\/5"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermodynamx.ch\/en\/wp-json\/wp\/v2\/comments?post=1741"}],"version-history":[{"count":4,"href":"https:\/\/www.thermodynamx.ch\/en\/wp-json\/wp\/v2\/pages\/1741\/revisions"}],"predecessor-version":[{"id":2011,"href":"https:\/\/www.thermodynamx.ch\/en\/wp-json\/wp\/v2\/pages\/1741\/revisions\/2011"}],"wp:attachment":[{"href":"https:\/\/www.thermodynamx.ch\/en\/wp-json\/wp\/v2\/media?parent=1741"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}